Testsystems
All articles

Know-how

Which rotor faults does a magnetic field scan reveal?

Faults in a rotor are rarely visible from the outside. In the magnetic field, though, every fault leaves a typical pattern, and the measurement makes it visible. The software’s verdict is pure arithmetic: it compares the values of every pole with your criteria and returns a pass or a fail. From the 3D and 2D visualizations and the key figures, the cause can usually be worked out. The fault patterns below show which pattern points to which fault.

How to read the fault patterns

The test bench measures the magnetic field across the rotor’s surface. Each pole shows as a swing up or down. The sketches show this curve in simplified form: dashed for a healthy rotor, red for the faulty one.

Further readingHow large a deviation must be to count as a fault is up to you. How that works is covered in How is the rotor tested?

Fault patterns by motor type

Some faults occur on several motor types, while others are typical of one particular type, such as shorted turns in an EESM rotor.

Shared by several motor types

  • }

    Weak or damaged magnet

    A weakly magnetized, chipped or cracked magnet lowers the peak and flux of its pole relative to the others.

    Applies to: PSMAFMLinear motors

  • }

    Reversed or missing magnet

    A magnet fitted the wrong way round, or not at all, shows up as a pole of the wrong polarity or a gap in the pole sequence.

    Applies to: PSMAFMLinear motors

  • }

    A part weak all over

    Every pole even, but all of them low: caught by target values from your specification or by comparison with a reference part.

    Applies to: PSMEESMAFMLinear motors

PSM Permanent-magnet synchronous motors

  • }

    Magnet out of position

    A magnet shifted in its pocket moves the pole’s center and changes the pole’s width, even when the magnet’s strength is right.

  • }

    Fault in an inner magnet layer

    In multilayer embedded designs a weak or broken magnet deep inside the rotor still changes the field at the surface, so it can be localized without taking the rotor apart.

  • }

    Skew outside tolerance

    On skewed rotors the magnets are deliberately offset along the axis. The bench measures how far the poles actually shift from one end of the rotor to the other, and so catches a skew angle outside tolerance.

EESM Externally excited synchronous motors

  • }

    Shorted turns in a pole coil

    A short between turns weakens the field of that one pole only, which stands out clearly from the other poles at the same current.

  • }

    Pole coil connected the wrong way

    A coil wound or connected in reverse produces a pole of the wrong polarity in the sequence.

  • }

    Resistance out of tolerance

    Four-wire measurement shows a winding or joint whose resistance deviates from the target before it heats up in service.

  • }

    Brush and slip ring wear

    Sparking and brush temperature are recorded, and lifetime tests show how the contact behaves over time.

AFM Axial flux motors

  • }

    Segment shifted on the disc

    A magnet offset in angle or radius moves the pole’s center and changes its field profile from inner to outer radius.

  • }

    Uneven distance to the face

    A disc that is not flat or not square to its axis shows as a field that rises and falls once per revolution.

Linear motors

  • }

    Pitch error at a segment joint

    Where two track segments meet, a gap or overlap shows as one pole pitch that differs from the rest.

  • }

    One segment weaker than the rest

    If the magnets of one track segment come from a different batch, they are all slightly weaker. Magnet by magnet this hardly shows; along the track it shows as a step in field strength at the segment joint.

Further readingWhich of these faults cause noise and vibration is covered in What are NVH issues?

Would you like to know more?

Suspect one of these faults in your rotors? We can measure it.