Testsystems

Magnetic field testing of EESM rotors

An externally excited rotor has no magnets. Its field comes from the rotor winding, energized through a slip ring and carbon brushes, so the field only exists while current flows.

On the test bench we supply that excitation ourselves, under conditions you define. Once the rotor is energized, the bench scans the rotor stack just as it does a permanent-magnet rotor.

We saw the need for EESM measurement early on, because EESM motors need no rare-earth magnets. Rare earths come from only a few supplier countries, and their prices fluctuate sharply.

  • Single sensor approx. 30 s – 5 min
  • Sensor array 8⁠–⁠15 s

Configure a test bench How pass/fail is decided

EESM Slip ring Carbon brushes Excitation Pole winding Sensor Rotation
Circumference, under excitation · Rotation

How it is measured

  1. Sensor array set to the diameter

    The sensor array is moved in close to the rotor, to match its diameter. You can save the setting for each of your rotor types.

  2. Contacted through the slip ring

    Slip ring contacting is automatic and interchangeable, so different rotor variants run on the same bench.

  3. Excitation you program

    The excitation runs in various current and voltage modes. Excitation current, ambient temperature and brush pressure are adjustable.

  4. Endurance and lifetime

    Lifetime testing · High-speed and endurance tests up to 24,000 rpm

EESM measurement on the single sensor test bench 0:39

What the scan shows

  • Flux density of every pole under a defined excitation current
  • Four-wire resistance measurement of the winding
  • Recording of current, voltage and temperature profiles
  • Detection of brush sparking and brush temperature
On every motor type: peak, polarity, width and center of every pole, pole symmetry and FFT. Evaluated against your criteria →

Faults typical of EESM rotors

  • }

    Shorted turns in a pole coil

    A short between turns weakens the field of that one pole only, which stands out clearly from the other poles at the same current.

  • }

    Pole coil connected the wrong way

    A coil wound or connected in reverse produces a pole of the wrong polarity in the sequence.

  • }

    Resistance out of tolerance

    Four-wire measurement shows a winding or joint whose resistance deviates from the target before it heats up in service.

  • }

    Brush and slip ring wear

    Sparking and brush temperature are recorded, and lifetime tests show how the contact behaves over time.

  • }

    A part weak all over

    Every pole even, but all of them low: caught by target values from your specification or by comparison with a reference part.

Overview of all fault patterns

Compare motor types

PSM EESM AFM Linear motors
Measured from CircumferenceCircumference, under excitationFace of the discAlong the track
Motion RotationRotationRotationLinear travel
Max. rotor diameter 250 mm250 mm——
Max. part length 500 mm500 mmOn request400 mm
Single sensor approx. 30 s – 5 minapprox. 30 s – 5 minapprox. 30 s – 5 min—
Sensor array 8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s
Special hardware —Slip ring contacting and programmable excitation——

Further reading

  • What are NVH issues?

    NVH stands for noise, vibration and harshness. Why NVH matters so much in electric motors, which rotor faults cause it, and where a magnetic field scan fits alongside your NVH test.

  • Which rotor faults does a magnetic field scan reveal?

    Typical faults in electric motor rotors and how each shows in the magnetic field – on permanent-magnet, externally excited and axial flux rotors and on linear motors.

Contract measurement

Test it on your own rotor first

Send us one of your rotors, or we come to your plant in Germany with a mobile test bench. You receive the 3D model of the field, the pole analysis and the measurement data – before you decide on a test bench of your own.