In an axial flux motor the magnets sit on the face of a disc and the field leaves the rotor axially, not radially. So the sensors face the disc rather than its circumference, and the scan covers the magnet track from its inner to its outer radius.

AFM rotors can be measured on our universal test bench or, for the highest precision, on our test bench adapted specifically to AFM rotors.

  • Single sensor approx. 30 s – 5 min
  • Sensor array 8⁠–⁠15 s

Configure a test bench How pass/fail is decided

AFM NSNSNSNSNS Sensor array Magnets Rotation
Face of the disc · Rotation

Universal test bench

One bench for 4 motor types

Universal test bench Sensor array Magnets Rotor Rotation
Rotor upright, sensor array in front of its face

AFM test bench

Adapted specifically to AFM rotors, for the highest precision thanks to minimal axial runout

AFM test bench Sensor array Magnets Rotor Rotation
Rotor lying flat, sensor array above it

How it is measured

  1. Disc turned on its axis, sensors facing it

    The rotor turns in the fixture with the sensors set at a defined distance in front of its face. The distance is adjustable, so the gap can match the air gap in the motor.

  2. Shifted between revolutions for finer tracks

    For a radial resolution finer than the sensor spacing, a linear axis shifts the sensor array along the radius by a fraction of that spacing between revolutions.

  3. Same software, same criteria

    Poles are evaluated with the same values and targets as on radial rotors.

CAD view of a test bench with a sensor array set up in front of an axial flux rotor.

What the scan shows

  • Axial flux density across the full magnet face
  • Magnetic imbalance analysis for each individual pole
  • Field profile from inner to outer radius
  • 3D field components Bx, By, Bz (single sensor)
On every motor type: peak, polarity, width and center of every pole, pole symmetry and FFT. Evaluated against your criteria →

Faults typical of axial flux rotors

  • }

    Segment shifted on the disc

    A magnet offset in angle or radius moves the pole’s center and changes its field profile from inner to outer radius.

  • }

    Uneven distance to the face

    A disc that is not flat or not square to its axis shows as a field that rises and falls once per revolution.

  • }

    Weak or damaged magnet

    A weakly magnetized, chipped or cracked magnet lowers the peak and flux of its pole relative to the others.

  • }

    Reversed or missing magnet

    A magnet fitted the wrong way round, or not at all, shows up as a pole of the wrong polarity or a gap in the pole sequence.

  • }

    A part weak all over

    Every pole even, but all of them low: caught by target values from your specification or by comparison with a reference part.

Overview of all fault patterns

Compare motor types

PSM EESM AFM Linear motors
Measured from CircumferenceCircumference, under excitationFace of the discAlong the track
Motion RotationRotationRotationLinear travel
Max. rotor diameter 250 mm250 mm——
Max. part length 500 mm500 mmOn request400 mm
Single sensor approx. 30 s – 5 minapprox. 30 s – 5 minapprox. 30 s – 5 min—
Sensor array 8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s
Special hardware —Slip ring contacting and programmable excitation——

Further reading

  • What are NVH issues?

    NVH stands for noise, vibration and harshness. Why NVH matters so much in electric motors, which rotor faults cause it, and where a magnetic field scan fits alongside your NVH test.

  • Which rotor faults does a magnetic field scan reveal?

    Typical faults in electric motor rotors and how each shows in the magnetic field – on permanent-magnet, externally excited and axial flux rotors and on linear motors.

Contract measurement

Test it on your own rotor first

Send us one of your rotors, or we come to your plant in Germany with a mobile test bench. You receive the 3D model of the field, the pole analysis and the measurement data – before you decide on a test bench of your own.