Testsystems

Magnetic field testing of linear motor magnet tracks

The secondary part of a linear motor is a magnet track: a row of magnets of alternating polarity, often assembled from several segments. Unlike with the rotors, it is not the part that moves here but the sensor array: it travels along the track and scans it over its length.

Linear tracks are measured with the sensor array, which covers the width of the track in one pass.

  • Sensor array 8⁠–⁠15 s

Configure a test bench How pass/fail is decided

LINEAR-MOTORS NSNSNSNSN Sensor array Segment joint Magnets Travel
Along the track · Linear travel

How it is measured

  1. Array moved along the track

    The sensor array travels on a linear axis over the full length of the magnet track, scanning it as it goes.

  2. Same software, same criteria

    Poles are evaluated with the same values and targets as on rotors.

Flat sensor array above a linear motor magnet track on the test bench.

What the scan shows

  • Flux density along the full length of the track
  • Pole pitch from pole to pole
  • Field across the width of the track
On every motor type: peak, polarity, width and center of every pole, pole symmetry and FFT. Evaluated against your criteria →

Faults typical of linear motor tracks

  • }

    Pitch error at a segment joint

    Where two track segments meet, a gap or overlap shows as one pole pitch that differs from the rest.

  • }

    One segment weaker than the rest

    If the magnets of one track segment come from a different batch, they are all slightly weaker. Magnet by magnet this hardly shows; along the track it shows as a step in field strength at the segment joint.

  • }

    Weak or damaged magnet

    A weakly magnetized, chipped or cracked magnet lowers the peak and flux of its pole relative to the others.

  • }

    Reversed or missing magnet

    A magnet fitted the wrong way round, or not at all, shows up as a pole of the wrong polarity or a gap in the pole sequence.

  • }

    A part weak all over

    Every pole even, but all of them low: caught by target values from your specification or by comparison with a reference part.

Overview of all fault patterns

Compare motor types

PSM EESM AFM Linear motors
Measured from CircumferenceCircumference, under excitationFace of the discAlong the track
Motion RotationRotationRotationLinear travel
Max. rotor diameter 250 mm250 mm——
Max. part length 500 mm500 mmOn request400 mm
Single sensor approx. 30 s – 5 minapprox. 30 s – 5 minapprox. 30 s – 5 min—
Sensor array 8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s
Special hardware —Slip ring contacting and programmable excitation——

Further reading

  • What are NVH issues?

    NVH stands for noise, vibration and harshness. Why NVH matters so much in electric motors, which rotor faults cause it, and where a magnetic field scan fits alongside your NVH test.

  • Which rotor faults does a magnetic field scan reveal?

    Typical faults in electric motor rotors and how each shows in the magnetic field – on permanent-magnet, externally excited and axial flux rotors and on linear motors.

Contract measurement

Test it on your own rotor first

Send us one of your rotors, or we come to your plant in Germany with a mobile test bench. You receive the 3D model of the field, the pole analysis and the measurement data – before you decide on a test bench of your own.