Testsystems

Magnetic field testing of PSM rotors

A permanent-magnet rotor carries its field in its magnets. A weak, damaged or misplaced magnet changes the field around the rotor, and that is where the test bench looks: it scans the field over the full circumference and length of the rotor and finds the part’s weak spots.

Our test bench checks rotors with anything from surface-mounted magnets to multilayer embedded magnet structures.

  • Single sensor approx. 30 s – 5 min
  • Sensor array 8⁠–⁠15 s

Configure a test bench How pass/fail is decided

PSM NSNSNSNS Sensor Rotation Magnets
Circumference · Rotation

How it is measured

  1. Test plan from the serial number

    A serial number scan selects the test plan automatically. The test plan sets, for example, how the sensor array approaches the rotor.

  2. Sensor array set to the diameter

    The sensor array is moved in close to the rotor, to match its diameter, so rotors of different diameters can run on the same bench. You can save the setting for each of your rotor types.

  3. Turned on its axis in the fixture

    The rotor turns in the fixture while the sensors scan its circumference.

Radial rotor clamped on the test bench, with the sensor array and 3D scanner positioned over it.

What the scan shows

  • Flux density over the full circumference and rotor length
  • Magnetic imbalance analysis for each individual pole
  • Skew angle
  • 3D field components Bx, By, Bz (single sensor)
  • Optional: runout and stack contour with the laser or the 3D scanner
On every motor type: peak, polarity, width and center of every pole, pole symmetry and FFT. Evaluated against your criteria →

Faults typical of PSM rotors

  • }

    Magnet out of position

    A magnet shifted in its pocket moves the pole’s center and changes the pole’s width, even when the magnet’s strength is right.

  • }

    Fault in an inner magnet layer

    In multilayer embedded designs a weak or broken magnet deep inside the rotor still changes the field at the surface, so it can be localized without taking the rotor apart.

  • }

    Skew outside tolerance

    On skewed rotors the magnets are deliberately offset along the axis. The bench measures how far the poles actually shift from one end of the rotor to the other, and so catches a skew angle outside tolerance.

  • }

    Weak or damaged magnet

    A weakly magnetized, chipped or cracked magnet lowers the peak and flux of its pole relative to the others.

  • }

    Reversed or missing magnet

    A magnet fitted the wrong way round, or not at all, shows up as a pole of the wrong polarity or a gap in the pole sequence.

  • }

    A part weak all over

    Every pole even, but all of them low: caught by target values from your specification or by comparison with a reference part.

Overview of all fault patterns

Compare motor types

PSM EESM AFM Linear motors
Measured from CircumferenceCircumference, under excitationFace of the discAlong the track
Motion RotationRotationRotationLinear travel
Max. rotor diameter 250 mm250 mm——
Max. part length 500 mm500 mmOn request400 mm
Single sensor approx. 30 s – 5 minapprox. 30 s – 5 minapprox. 30 s – 5 min—
Sensor array 8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s8⁠–⁠15 s
Special hardware —Slip ring contacting and programmable excitation——

Further reading

  • What are NVH issues?

    NVH stands for noise, vibration and harshness. Why NVH matters so much in electric motors, which rotor faults cause it, and where a magnetic field scan fits alongside your NVH test.

  • Which rotor faults does a magnetic field scan reveal?

    Typical faults in electric motor rotors and how each shows in the magnetic field – on permanent-magnet, externally excited and axial flux rotors and on linear motors.

Contract measurement

Test it on your own rotor first

Send us one of your rotors, or we come to your plant in Germany with a mobile test bench. You receive the 3D model of the field, the pole analysis and the measurement data – before you decide on a test bench of your own.