Testsystems

Magnetic Field Testing

Example measurements

Browse example measurements for the rotor types or fault patterns that interest you. The measurements were taken on real rotors on our test benches. For now we can publish only one measurement, but we are working on demonstrating the evaluation of an EESM rotor soon.

  • Schematic side view of the rotor as a cylinder, looking at pole 2. Along each pole lie two rows of 4 magnet pieces. Marked red is the area of pole 2 between about 80 and 100 mm axial position, where the field is weaker.Pole 2 · S: weaker between about 80 and 100 mmPole 1 · NPole 3 · N20406080100120140Axial position (mm)
    • PSM
    • 8 poles
    • V-shaped architecture
    • Weak/damaged magnet

    8-pole PSM rotor with one weak pole

    In a way, this rotor is where our company began. During prototype development, the NVH analysis showed conspicuous vibration problems, which could only be traced back to the rotor’s magnetic field after a lengthy investigation. A magnetic field analysis of the rotor would have revealed the cause straight away. That is how the development of our first test bench began…

    Views: Field map · Single-signal view · Field FFT

Contract measurement

Test it on your own rotor first

Send us one of your rotors, or we come to your plant in Germany with a mobile test bench. You receive the 3D model of the field, the pole analysis and the measurement data – before you decide on a test bench of your own.